Product Details:
Minimum Order Quantity | 1 Piece |
Cabinet Material | Mild Steel |
Main Filter | HEPA Filter |
Electric Supply | 230 V |
Noise Level | Less than 65 db |
Working area size | 4x2 ft |
Product Details:
Minimum Order Quantity | 1 Piece |
Cabinet Material | Mild Steel |
Main Filter | HEPA Filter |
Sterilization | UV Germicidal Tube |
Electric Supply | 230 V |
Noise Level | Less than 65 db |
Model Number | RI03 |
Product Type | Bio Safety |
Lighting Type | LED |
Airflow System | Megnelik Geuj |
Brand | Rombai |
Size | 3x2 ft |
Inflow Velocity | 90 FPM |
Specifications:
Supply Voltage(V): 220V 50Hz
Cleanliness: 100 grade@≥0.5μm (FBI209E )
Number of colony: ≤0.5/utensil.time(Φ90mm cultivation utensil)
Average wind speed: 0.3-0.6M/S(Adjustable)
Noise: ≤62αB(A)
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Rombai |
Lighting Type | Electrical |
Power | Single Phase |
Usage/Application | Pharmaceutical Sector |
Material | Mild Steel |
Main Filter | HEPA Filter |
Biosafety Level | BSL 1 |
Noise Level | Less than 65 db |
Specifications:
• The main body should be mad in mild steel (Heavy gauge- 19 G)
• Table top and working zone should be made of stainless steel (304 grade)- Heavy gauge- 20 G
• Table top should be in two parts: Front perforated portion 5” in size, Non-perforated working zone, Work Area should be approximately 2 X 2, 3 X 2, 4 X 2 with shutter opening of 489 mm
• Air Flow should be vertical down low with 70 % Circulation 30 % exhaust
• Cleanliness level should be less than 3.5 particles/ liter of 0.5 mm and larger
• Noise Level should be less than 65 dB
• Vibration level: Less than 2.3 mm
• Average air ow should be 90±20 fpm
• Door fully automatic
• HEPA filters should be Mini Plate with 99.99% efficiency for 0.3 microns with integral metal guards & filter frame gaskets and manufactured in class 1000 super clean air conditioned Air pressurization system should be statically and dynamically balanced, environment for longer life.
• Fitted with special vibration reducing the system to suit low noise and vibrations. UV lamp should be in working zone (40 microwatts/ square cm at 254 mm or better) and placed so that the operator cannot see directly i.e. eyes should be always protected. Should have Rehabitable pre-filters should have the efficiency of more than 80%. Should have Switches & Electrical sockets outlets for 15/5 amp. Should have Pressure Monitors like Magnehelic gauge are required to indicate pressure drop air. Exhaust blower should be capable for 100% exhaust interconnected with supply air blower; the system should only start when the negative pressure is developed Back holes should be there on vertical walls to provide more work area on Should have Switches & Electrical sockets outlets for 16 amp. Suitable power supply 230 volts a/c
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Main Filter | HEPA Filter |
Sterilization | UV Germicidal Tube |
Electric Supply | 230 V |
Noise Level | Less than 65 db |
Product Type | Bio Safety |
Airflow System | Menelik Geuj |
Brand | Rombai |
Size | 2 X 2 ft |
Inflow Velocity | 100 FPM |
Downflow Velocity | 90 FPM |
Constructions | MS |
Fluorescent Lamp | 1 NOG |
General Use | For Lab |
No Of Hepa Filter | 2 |
Width | 1300 IN MM |
Class | Mean inflow velocity to achieve operator protection | Mean down flow velocity to achieve product protection |
I | > 0.7 m/s – 1.0 m/s | Not Applicable |
II | ≥ 0.4 m/s | 0.25 m/s – 0.50 m/sec |
III | ≥ 0.7 m/s with one glove removed | Not Applicable |